Gasgoo Munich- At the 2026 China Auto Charging and Swapping Ecosystem Conference on November 18, Su Xin, chairman and CEO of Guangdong Yineng Shidai Technology, put the problem of "inflated ratings" in charging modules front and center.
Behind the race for high-power fast charging lies a question that both EV owners and charging station operators tend to overlook: can a charger's rated output hold up under prolonged, high-temperature conditions? Su Xin categorizes inflated ratings into two types — insufficient vehicle compatibility and thermal derating. The latter is more insidious, but takes a far greater toll on the actual charging experience.
Charging modules are the core component of any charging pile, and module efficiency directly dictates a station's power loss and operating costs. Every percentage-point gain in efficiency compounds over time, with tangible effects on electricity bills and equipment cooling demands.
Two Types of Inflation: Compatibility Shortfalls and Thermal Derating
Some modules avoid disclosure when faced with limited compatibility scenarios, Su Xin noted, leaving many vehicle models inadequately supported. That, he said, is the first form of inflated rating.

Image source: Gasgoo
He focused on derating-related inflation. Charging modules lose output in high-temperature environments: on hot days, a module rated at 50 or 60 kW may drop to around 40 kW. A 400 kW charger, for instance, might only push to the low 300 kW range for a few hours around midday in summer. Pushing the power higher would introduce safety risks and, in severe cases, trigger equipment failure.
Power shrinkage is now a widespread phenomenon among high-power modules, Su Xin argued. At lower power levels, the issue was barely visible — most products could maintain output at 55°C or higher. But once modules above 60 kW — particularly 60 kW and 80 kW units — entered the market in volume, the problems began surfacing en masse.
Heavy-Duty Truck Chargers: Can't Last an Hour
Heavy-duty truck chargers are the hardest hit, according to Su Xin. These high-power units generate substantial heat, meaning they don't need hot weather to start derating — the equipment's own operation produces plenty. A 400 kW charger, for example, might hold its rated output for the first 40 minutes, then slip to the low 300 kW range as heat builds up.
As for the scale of the problem, Su Xin's team conducted a market survey from the enterprise side and arrived at a preliminary estimate: among high-power modules rated 60 kW and above, roughly 70% carry inflated ratings. In other words, buy ten high-power chargers, and six or seven will fail to reach their rated output after 40 minutes to an hour of operation.
The effects of derating cascade through the station. When actual output falls short, fewer vehicles can be served simultaneously, and peak-hour wait times stretch longer. If modules remain in high-load cooling states for extended periods, equipment aging and failure rates climb accordingly. For station operators, the charging capacity and return models calculated at rated power during procurement may simply fall apart under high-temperature, prolonged-use conditions.

Image source: Gasgoo
As for root causes, Su Xin believes some manufacturers cut costs by overclocking: a module rated at 60 or 80 kW may actually be a 40-something or 50-something kW unit pushed beyond its design limits — the only way to bring the price down. He frames this as quality erosion driven by cut-throat competition. In his view, the charging module industry has entered its "final round," with only a handful of companies still capable of producing high-power modules. At this stage, what matters most is the integrity of the remaining players.
If modules and equipment aren't effectively tested at the procurement stage, problems could emerge en masse within a year or two. The first thing to check when buying equipment is whether it can sustain power output over extended operation — that's the baseline standard.
Su Xin positions charging and swapping infrastructure as critical to China's high-quality development. No matter how high the power targets or how low the per-watt costs, he argued, quality should never be sacrificed. That, he said, is a bottom line the industry must collectively hold.
On the technology front, Guangdong Yineng Shidai Technology launched a product this year with a peak conversion efficiency of 99%. According to the company, the product maintains a comprehensive efficiency above 98.5% across a wide voltage range of 300 to 1,000 volts and relies on natural cooling. At 100 kW per single module, it is a first in its class.
Su Xin also revealed that Guangdong Yineng Shidai Technology will unveil a crowdfunded new product at a trade show in Shenzhen next week. The product is based on research with station operators and, with the support of an industry association, incorporates operators' design input. Partners participated in the initial definition and crowdfunding before the product was brought to market.
High-power fast charging is the direction of charging network upgrades. As module power ratings climb ever higher, whether equipment can hold its output under high-temperature, prolonged-use conditions — beyond what the spec sheet promises — is becoming a lesson that station procurement and industry acceptance testing still need to learn. If price competition comes at the cost of power shrinkage and quality erosion, the bill ultimately lands with station operators and EV owners.